Data Center Design & DCIM
Instrument the facility. Forecast the capacity. Prove the efficiency.
Jiva Technologies assesses, designs, integrates, and supports Data Center Infrastructure Management (DCIM) environments across single and multi-site facilities. The practice covers asset and rack management, power and cooling monitoring, environmental sensors, digital twins, alerting and reporting, capacity planning, and data-centre design and build.
Integrates with existing identity, ITSM, monitoring, and Building Management Systems so facility, IT, and sustainability stakeholders share one operating picture across sites.
Explore the practice
Asset & Inventory Management
One authoritative record for every asset in the facility.
Discover, catalogue, and maintain servers, network, storage, PDUs, cabling, and rack-mount hardware with lifecycle, warranty, ownership, and location detail. Integrated with CMDB, ITSM, procurement, and finance so physical, virtual, and cloud assets stay in a single source of truth for install, audit, and refresh.
- Automated Discovery
- CMDB Alignment
- Warranty & Lifecycle
- Structured Cabling Records
Rack & Capacity Management
Plan deployments against instrumented headroom.
Live rack elevations, U-space, weight, power-per-rack, and port allocation with reservation workflows tied to enterprise ITSM change tickets. Model rack refreshes, HCI, and high-density AI clusters against actual capacity before floor space, power, and cabling are committed.
- Rack Elevations
- U-Space & Weight
- PDU & Port Headroom
Power & Cooling Monitoring
Measure every watt across UPS, PDU, and cooling plant.
Unified telemetry from UPS, smart PDUs, CRAC / CRAH, in-row cooling, busway, generators, and ATS across Schneider, Vertiv, Eaton, Rittal, and multi-vendor estates. Real-time PUE, WUE, thermal maps, phase balancing, and sub-metering for facilities, IT operations, and sustainability reporting.
- UPS & Smart PDU
- CRAC / Busway Telemetry
- PUE / WUE Tracking
Environmental Monitoring
Catch anomalies before they become outages.
Rack-inlet temperature, aisle humidity, water-leak, VESDA smoke, differential pressure, door and rack-access sensors across the white space. ASHRAE-aligned thresholds, containment integrity, and multi-channel alerting integrated with ITSM and incident-response workflows.
- Temperature & Humidity
- Leak & Smoke Detection
- Airflow & Containment
3D Visualization & Digital Twin
See the facility. Simulate the change. Prove the design.
Interactive floor plans, 3D rack elevations, and live digital twins with sensor overlays, cable-path tracing, and airflow simulation. Multi-site geo views, as-built handover packs, and optional AR / VR walkthroughs for remote assistance and design review.
- Floor Plans & 3D Racks
- Digital Twin
- Cable Tracing
Alerts, Analytics & Reporting
Right alert. Right person. Right report.
Threshold, trend, and anomaly alerts routed through incident alerting, chat, and ITSM. Role-based dashboards for facilities, operations, and executive stakeholders with sustainability, audit, and BI outputs feeding Microsoft Power BI, Tableau, and Qlik.
- Threshold & Anomaly Alerts
- Executive Dashboards
- Audit & ESG Packs
Capacity Planning & Forecasting
Plan the next five years on evidence, not opinion.
Trend, scenario, and TCO modelling for growth, consolidation, refresh, high-density AI, and cloud repatriation. Reservation pipelines with automated approval, stranded-capacity recovery, and board-ready three to five year investment roadmaps grounded in live utilisation data.
- Trend & Scenario Modelling
- AI / High-Density Planning
- Cloud vs On-Prem TCO
Data Center Design & Build
Design, build, and commission facilities with DCIM baked in.
Greenfield and brownfield data-centre design aligned to Uptime Institute Tier II, III, and IV, TIA-942, and EN 50600. Containment strategies, precision cooling, resilient power distribution, structured cabling, and commissioning delivered as one design authority with instrumentation from day one.
- Tier II / III / IV
- Containment & Cooling
- Power Distribution
Common facility gaps
- Spreadsheets drift from the real estate
Asset, cabling, and rack records live across Visio, Excel, and tribal knowledge — every audit and install begins with a physical walk-through.
- Stranded power, space, and cooling
Racks look full while PDUs sit half-loaded and cold-aisle capacity goes unused, blocking new deployments the facility could actually support.
- Environmental issues surface too late
The first sign of a thermal or humidity excursion is often a hardware failure, not an alert routed to facilities and IT in time to intervene.
- No unified sustainability or capacity view
PUE, energy cost, capacity headroom, and refresh forecasts sit in separate tools, leaving ESG committees and IT leaders without a shared operating picture.
Delivery approach
A practical Data Center Infrastructure Management (DCIM) lifecycle covering facility assessment, platform architecture, multi-vendor integration, instrumentation, and ongoing operational support.
- 01Assess
Survey the facility, baseline assets, review power and cooling telemetry, sensor coverage, capacity records, and integration surface across DCIM, BMS, ITSM, and monitoring tooling.
- 02Design
Define the target DCIM platform, asset and rack data model, sensor layout, dashboard set, alerting rules, workflow integration, and reporting cadence per stakeholder group.
- 03Implement
Deploy platforms, instrument racks and plant, import and cleanse asset data, build digital twins, integrate ITSM, BMS, and monitoring, and train operations teams.
- 04Support
Tune alerts and thresholds, review capacity and sustainability reports, maintain integrations, update inventory, and support platform lifecycle upgrades and vendor coordination.
End-to-End IT Integration and Support
From assessment and solution design through implementation, remediation, ongoing support, and lifecycle optimization.
Fix What's Broken — Remediation Sprints
Stranded rack capacity, blind spots in power/cooling, stale asset records or DCIM tooling that no-one trusts? We run fixed-scope DCIM remediation sprints to restore data quality and operational visibility.
- Asset inventory reconciliation, rack elevation cleanup and CMDB sync
- Power, cooling and environmental sensor coverage and threshold tuning
- Capacity planning models, alerting hygiene and reporting rebuild
Support & Maintenance — AMC-Backed
Keep DCIM data accurate and the data-centre running efficiently — asset governance, sensor care and vendor escalation under a Jiva AMC.
- L1/L2/L3 DCIM platform support with quarterly data-quality reviews
- Preventive maintenance for power, cooling and environmental sensors
- Capacity, sustainability and utilisation reporting for facilities and IT
Continue exploring
Related services
- IT Infrastructure & Cloud
Design and support the compute, storage, network, and hybrid-cloud foundations that populate racks and consume facility capacity.
- Managed Infrastructure & Cloud
Operate compute, storage, network, and cloud platforms with monitoring, remediation, patching, and lifecycle support across sites.
- Cybersecurity
Coordinate identity, endpoint, network, cloud, monitoring, and incident-response controls that protect facility management and OT networks.
- Business Continuity & Disaster Recovery
Align business priorities, backup, replication, disaster recovery, cyber recovery, testing, and operational support within one resilience programme.
- Sustainability & Green IT
Advance energy efficiency, circular IT, carbon accounting, and sustainable workplace technology across data-centre and enterprise estates.
- Surveillance, ELV & AV Systems
Coordinate CCTV, access control, intrusion, intercom, fire, PA, AV, and digital signage across the physical estate under one design authority.
Instrument the facility
Build a DCIM-instrumented data centre
Review asset records, rack capacity, power and cooling telemetry, environmental sensors, and reporting cadence against operational and sustainability objectives. Jiva Technologies can consult, design, implement, remediate, maintain, and manage a phased DCIM programme aligned to facility priorities.