Data Center Design & Build

Design to Tier. Build to standard. Commission to prove.

Greenfield and brownfield data-centre design and build engagements aligned to Uptime Institute Tier standards, TIA-942, and EN 50600 across power, cooling, cabling, security, sustainability, and DCIM.

"Designed for the workload. Built for the standard."
Design Standards
Tier-aligned

Uptime Tier II / III / IV, TIA-942, EN 50600.

Delivery Scope
Concept-to-COM

Shell, MEP, IT, DCIM, and commissioning.

Sustainability
Green-by-design

Free cooling, PPA supply, target-PUE modelling.

What we deliver

  1. Tier II / III / IV Alignment

    Design to Uptime Institute Tier II, III, and IV concurrent maintainability and fault-tolerance requirements alongside TIA-942, EN 50600, and local compliance.

  2. Hot / Cold Aisle Containment

    Full or partial hot and cold aisle containment, chimney cabinets, and airflow management to reduce mixing and improve cooling effectiveness.

  3. Power Distribution Design

    Medium and low voltage distribution, static and rotary UPS sizing, generator plant, ATS strategy, N+1 and 2N redundancy, and IEC / NEC-compliant switchgear layout.

  4. Precision Cooling Design

    CRAC / CRAH, in-row cooling, rear-door heat exchangers, adiabatic and free-cooling economisers, and liquid or immersion cooling for high-density racks.

  5. Structured Cabling & MDA / IDA

    MDA, IDA, HDA, and ZDA design to TIA-942, fibre and copper backbones, patch-panel strategy, and future-proof pathway design for high-speed uplinks.

  6. Physical Security & Access

    Multi-layer access design, mantrap airlocks, biometric readers, cabinet-level locks, CCTV coverage, and secure visitor workflow integrated with the access control system.

  7. Green IT & Sustainability

    Free cooling, waste-heat recovery, renewable and Power Purchase Agreement supply, low-GWP refrigerants, and target-PUE design engineered from concept.

  8. Commissioning & Handover

    Level 1 to 5 commissioning, Integrated System Testing (IST), load-bank testing, as-built drawings, O&M manuals, and operator training at project closeout.

Signals we hear

Why teams call us

4 recurring gaps
  • Design and operations decouple at handover

    Facilities inherit a build without the instrumentation, records, and standards needed to operate it against the design intent.

  • Brownfield upgrades outrun the base build

    New workloads require power, cooling, and containment that the existing shell was never designed for, exposing constraints during install.

  • Sustainability is bolted on late

    Free cooling, waste-heat recovery, and target-PUE decisions are revisited after construction, when the biggest gains are already unavailable.

  • Commissioning evidence is incomplete

    As-built drawings, integrated test results, and O&M documentation lag physical work, delaying operational and audit readiness.

How we engage

Our approach

Data-centre design and build engineered around tier alignment, integrated services coordination, sustainability by design, and evidence-backed commissioning.

  1. Assess

    Survey site or existing facility, workload mix, tier and compliance targets, sustainability goals, and integration with corporate IT and security estates.

  2. Design

    Develop concept, schematic, and detailed design across power, cooling, cabling, security, DCIM, and sustainability, coordinated with third-party disciplines.

  3. Build & Commission

    Manage construction and installation with quality control, run levelled commissioning and Integrated System Testing, and deliver as-built and operational documentation.

  4. Support

    Support operational handover, DCIM instrumentation, statutory testing cadence, and ongoing modernisation as workloads, density, and standards evolve.

Fix What's Broken — Remediation Sprints

Stranded rack capacity, blind spots in power/cooling, stale asset records or DCIM tooling that no-one trusts? We run fixed-scope DCIM remediation sprints to restore data quality and operational visibility.

  • Asset inventory reconciliation, rack elevation cleanup and CMDB sync
  • Power, cooling and environmental sensor coverage and threshold tuning
  • Capacity planning models, alerting hygiene and reporting rebuild
Request a remediation scope

Support & Maintenance — AMC-Backed

Keep DCIM data accurate and the data-centre running efficiently — asset governance, sensor care and vendor escalation under a Jiva AMC.

  • L1/L2/L3 DCIM platform support with quarterly data-quality reviews
  • Preventive maintenance for power, cooling and environmental sensors
  • Capacity, sustainability and utilisation reporting for facilities and IT
Explore AMC & support contracts

Continue exploring

Design, build, and commission with confidence

Plan a data-centre design, build, or modernisation engagement

Review site conditions, workload mix, tier and compliance targets, sustainability goals, and existing constraints. Jiva Technologies can assess, design, deliver, and commission new build and brownfield modernisation programmes with DCIM instrumentation integrated from day one.