Fire Alarm & Life Safety
Detect early. Alert everyone. Evacuate safely.
Jiva Technologies designs, integrates and supports addressable fire detection, notification and building-wide cause-and-effect commissioned to NBC 2016, NFPA 72, EN 54 and BS 5839. Life-safety evidence is maintained through statutory testing and AHJ-aligned documentation.
NBC 2016, NFPA 72, EN 54 and BS 5839.
HVAC, lifts, doors, PA and access wired into the fire matrix.
Statutory testing, faults and remediation documented.
What we deliver
Addressable Fire Detection
Analogue-addressable smoke, heat and multi-criteria detectors, aspirating smoke detection (VESDA) and beam detectors for high-ceiling spaces engineered per site risk.
Fire Alarm Control Panels
EN 54-2 / -4 compliant control panels, networked multi-panel campuses, graphical annunciators and cause-and-effect logic engineered per site and fire strategy.
Sounder / Strobe Notification
Coded sounders, wall and ceiling strobes, VADs and combined notification devices designed to audibility and visibility standards across all occupied areas.
Voice Evacuation Integration
Cause-and-effect integration with EN 54-16 PA / VA for automated pre-alarm, phased evacuation and all-clear messaging per fire zone and floor.
Suppression System Interfacing
Monitoring and release interfaces for FM-200, Novec, CO2, water-mist and sprinkler systems, kitchen ANSUL and dedicated hazard suppression.
BMS / HVAC Damper Control
Automatic HVAC shutdown, damper actuation, lift homing, magnetic door hold-release and access-control release driven by the fire cause-and-effect matrix.
NBC / NFPA / AHJ Compliance
Design and commissioning to NBC 2016, NFPA 72, BS 5839 and local AHJ, with third-party validation and occupancy-certificate support.
Statutory Testing & Log-Book
Scheduled statutory testing, device replacement, panel firmware maintenance, log-book upkeep and breakdown response under support contracts.
Why teams call us
- AHJ acceptance stalls occupancy
Design submissions, third-party validation and commissioning evidence are incomplete, delaying occupancy certificates and insurance cover.
- Cause-and-effect not fully commissioned
HVAC shutdown, lift homing, door release, ACS fail-safe and voice evacuation do not fire correctly during test scenarios because integration was never fully exercised.
- Legacy conventional panels reaching end-of-life
Aging conventional panels lack addressable diagnostics, remote monitoring and integration surfaces expected by modern fire strategies.
- No maintained log-book or test evidence
Statutory testing, battery checks and fault records are not kept, invalidating AHJ acceptance and audit evidence at renewal or incident review.
Our approach
Fire and life-safety delivered as a code-driven engineering discipline with fully exercised cause-and-effect, third-party validation and evidenced statutory testing.
- Assess
Fire strategy review, detector and panel inventory, cause-and-effect audit, AHJ evidence check and interface review with HVAC, lifts, ACS and PA / VA.
- Design
Zoning, detector selection, panel and network topology, cause-and-effect matrix, suppression interfaces and integration with BMS and life-safety systems.
- Deploy
Cabling, device and panel installation, cause-and-effect commissioning, third-party validation, AHJ walkthrough support and log-book handover.
- Operate & Improve
Scheduled statutory testing, device replacement, panel firmware, log-book upkeep, remediation of faults and AHJ evidence packaging under support contracts.
End-to-End IT Integration and Support
From assessment and solution design through implementation, remediation, ongoing support, and lifecycle optimization.
Fix What's Broken — Remediation Sprints
Unreliable CCTV, access-control gaps, ELV / AV fault tickets or fire-safety systems drifting out of compliance? Jiva Technologies runs fixed-scope remediation sprints across surveillance, access, ELV and AV estates.
- CCTV, access-control, intrusion and intercom coverage-gap closure
- ELV, AV, public-address and digital-signage integration and cabling cleanup
- Fire-life-safety alignment and evidence pack for facility and compliance audits
Support & Maintenance — AMC-Backed
Keep surveillance and physical systems running after handover — device health, platform hygiene and vendor coordination under a Jiva AMC.
- L1 / L2 / L3 support for CCTV, access-control, ELV and AV platforms
- Preventive maintenance visits, firmware, sensor calibration and spares management
- Vendor coordination, licence renewal and periodic system-health reviews
Continue exploring
Related services
- Public Address & Voice Evacuation
Zoned paging, background music, and EN 54-16 voice evacuation integrated with fire cause-and-effect logic, BMS, and life-safety controls.
- Access Control & Attendance
Unify biometric, card, and mobile-credential access with identity, HRIS, visitor management, and SOC-linked event correlation across sites.
- CCTV & Video Surveillance
Design and integrate IP cameras, VMS platforms, AI analytics, evidence retention, and cyber-integrated video operations for single and multi-site estates.
- Networking & Connectivity
Structured cabling, PoE switching, network segmentation, and wireless engineered to carry surveillance, ELV, and AV traffic reliably across sites.
- Managed IT Services
Operate infrastructure, endpoints, cloud, and physical-systems platforms through service desk, monitoring, remediation, and lifecycle support.
Protect occupancy and evidence
Ready to modernise fire detection and life-safety cause-and-effect?
Review fire strategy, detector and panel inventory, cause-and-effect matrix, AHJ evidence, HVAC / lift / ACS / PA integration and statutory testing records. Jiva Technologies can assess, design, supply, integrate, remediate, modernise and support a compliant fire and life-safety programme.